Agronomy Journal Grow Your Career With ASA
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Published online 1 November 1993
Published in Agron J 85:1192-1197 (1993)
© 1993 American Society of Agronomy
677 S. Segoe Rd., Madison, WI 53711 USA
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Goyal, S. S.
Right arrow Articles by Rains, D. W.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Goyal, S. S.
Right arrow Articles by Rains, D. W.
Agricola
Right arrow Articles by Goyal, S. S.
Right arrow Articles by Rains, D. W.

Simultaneous Determination of Total Sodium, Potassium, Magnesium, and Calcium in Plant Tissues Using Acid Digestion and Ion Chromatography

Sham S. Goyal*, Ahmed A. R Hafez and Donald W. Rains

Dep. of Agronomy and Range Science, Univ. of California at Davis, Davis, CA 95616.

* Corresponding author.

Sodium, K, Mg, and Ca in plant tissue were measured by single column ion chromatography (SCIC) as an alternative to traditional methods such as atomic absorption spectrophotometry (AAS) or inductively coupled plasma-atomic emission spectrophotometry (ICPAES). Interference of the NH4 peak on the Na peak in SCIC was eliminated by removal of NH4 ions by drying the nitric-perchloric acid plant digest at 350 °C. Cations were separated using an IC-Pack CM/D column with 0.1 mM EDTA + 3 mM HNO3 as eluent. Inclusion of 10% (v/v, = 1.89 M) acetonitrile in the eluent shortened the retention time of divalent cations by 22% compared with the time without acetonitrile. The Na, K, Mg, and Ca content of plant samples analyzed with this technique agreed closely with certified values provided by the National Institute of Standards and Technology (NIST). The lower limit of detection of SCIC for Na, K, Mg, and Ca were 0.05, 0.2, 0.025, and 0.05 mg L–1, respectively, using a 100-µL sample. The response of peak areas as a function of solute concentration was linear up to 10 mg L–1 of each cation. The SCIC method was cheaper than AAS or ICP, and faster than AAS, mainly due to simultaneous analyses of all four cations. SCIC did not generate hazardous and toxic waste and thus did not require special disposal procedures.

Received for publication October 27, 1992.





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
The SCI Journals Crop Science Vadose Zone Journal
Journal of Natural Resources
and Life Sciences Education
Soil Science Society of America Journal
Journal of Plant Registrations Journal of
Environmental Quality
The Plant Genome
Copyright © 1993 by the American Society of Agronomy.